Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why transformer ratings in kva?

Answer Posted / manoj prabhakar

1> Both the losses of the transformer is independent of the
power factor (cos phi), which means a transformer would not
make any change in the power factor, since both the losses
viz copper loss(depends on current) and iron loss(depends
on voltage) are independent of power factor, that is why a
Transformers rating is not on kW, but on KVA..

2> iron loss depend upon vtg & cu loss depend upon current
it threrotical also
we don't know load is pure resitive or inductive
so transformer rating in KVA
b'coz in res load KW=KVA, inductive KVA=KW/COSpi

3> In all A.C. machines (which includes motors whose rating
are in KW )iron losses are proportional to voltage & copper
losses are proportional to current.
The machine rating is given in terms of its output. The
transformer output is electrical energy & thus its rating
is same as energy i.e. KVA.
Same is the case with generator

4> actually rating of a equipment depends upon heat , which
depends upon loss. as in transformer both copper loss &iron
loss dont depend upon power factor . so transformer rating
is in kva.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why i receive the GCU fault in my DG Sychronization panel . what all the factors considered for this fault .

2165


I have 2500KVA transformer delta/star,13.8KV/380V provided with LV 4000A breaker. Already I have 2300KW motor feeder with a full load 90%. Is it possible to connect another 1600A from that breaker? If so how the calculation is done?

3761


What was your role in the silicon evaluation/product ramp? What tools did you use?

1909


what id a dry type transformers and its function ?

1712


define reflection method?

1891


which type of cabel

2355


How to calculate phase to phase difference ?

2187


What will happen if we on 200kvr capacitor bank(11kv in bus)If there is low load on transformer (1.5 mva 33/11 kv)

1519


why power not passes in plastic and rubber material

1904


i have total 8 dg sets for synchronizing and 2 buscoupler,1 sectoin dg no 1,2,3,and 2 sectoin dg no 4,5,6,and last section dg no 7,8 ....if buscupler no 1 and 2 is off mode ..than dg no 1,2,3,will synchroniz of another dg sets?

1776


Enlist four components of electrive drives.

1776


Incoming line 11kv And transformer capacity is 2500kva. Consumption load is 1300A. Then fuse capacity is 11kv line.

1628


in 6.6 kv vaccum circuit breaker vaccum bottole vaccum capacity ????

1947


What is the rating factor for copper cable ( Specific value according to the type of laying ) & the voltage drop?

1811


How is the resonant peak, resonant frequency, and bandwidth determined from nichols chart?

1032