Answer Posted / mohammed abbas
Instrumentation is branch of science which deals with
measuring,contolling and monitring various paramenter of
process like,temp,flow,level,pressure,
chimical parameter like,ph,density,etc
mechanical parameter like vibration,motion,etc
electrical parameter like current,voltage (vfd)
biomedical parameter
etc.
it is smilar to humanbeing funtioning
ex:-if a man driving a car at 100k/h speed on high way if
he find and jump ,he will reduce its speed to avoide
accident.
seeing the jump:-is sensing or measuring
action taken:-is maniuplation or camputaion
reduse the speed:-monitoring
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
dear friends, i have seen flow as the selection critriea in presure guage (bourdon tube) and i would like to know what is the relation between flow and performance of pressure guage other parameters i found in the data sheet are pressure max. 1ksc temperature max. - 50 deg c line size - 80NB operating range - 1ksc pr. guage range - 0-2 ksc thank u,
How digital input and digital output 's are working in dcs
Hi Friends i am going to write BARC written test by this month 20th (20-5-2008). So please if any body knows the details about this or having previous question papers pls mail me to kkumarei@gmail.com. For Suggestions give one message to 9962122264
why we are using digital signals for I/O & how to measure this signals is getting or not ?
what is wave length were using ?
what is commisioning procedure,2)what is is the main work in commisioning in the field tx to dcs, plz send me detail
A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?
POSSITIVE PULSE IS APPLIED TO AN INVERTER INPUT.THE TIME FROM THE LEADING EDGE OF THE INPUT TO THE LEADING EDGE OF THE OUTPUT IS 10 ns. THE TIME FROM THE TRAILING EDGE OF THE INPUT TO THE TRYLING EDGE OF THE OUTPUT IS 8 ns. WHAT ARE THE VALUES OF tPLH and tPHL?
What is the difference between working pressure and calibration pressure of a control valve
What is cut off relay? And why use in PLC and DCS?
Which products are available in the Mass Systemswitch and System Manager AC range?
basic connection and principle of axial shift sensor n differential sensors in tubine describes n draw......
Which type of diaphragm use in costic line, dm water line, natural gas line, oil line?
I want to measure and control level in tank of size 10*5 filled with gasoline, so plz give me the solution with clear details. how to select transmitter and sensors.
how do we commission inergen system?