What does Dew point -40C mean in an air drying unit.
Answer Posted / samy
Air dew point is -40C because of decC and decF are meet in -40
Is This Answer Correct ? | 1 Yes | 5 No |
Post New Answer View All Answers
What are the main terms in unit operations? What are its characteristics?
What effect does choking a vertical thermosiphon have on the heat transfer rate?
Where the Induced draft, forced draft & balanced draft furnace are to be used? Selection of furnaces are based on which criteria?
X is strong but has a very low density (1% of traditional earth materials.) and hence light weight. It is a recyclable material. The compression behaviour of X is strain rate dependent. Higher strain rates result in higher initial modulus and higher compression strength. It can also withstand unlimited number of cycling loading provided the repetitive loads are kept below 80% of the compressive strength. The internal structure of the material includes air-traps which make it poor heat conductor. X is non- biodegradable and chemically inert in both soil and water. Most acids and their water solutions do not attack it; however strong oxidizing acids do. Solvents which attack X include esters, ketones, ethers, aromatic and aliphatic hydrocarbons and their emulsions, among others. It does not support bacterial/fungal growth as well .It also has significant acoustic properties and effectively reduces the transmission of airborne sound. X is combustible and should not be exposed to open flame or other ignition sources. Combustion products are carbon monoxide, carbon dioxide, water and soot. Long-term exposure to sunlight causes yellowing and a slight embrittlement of the surface due to ultraviolet light. X is able to withstand the rigours of temperature cycling, assuring long-term performance.
Explain the steps required to design a vapor-liquid separator or flash drum?
For a heat exchanger, will the overall heat transfer coefficient increase along with an increase in lmtd (log mean temperature difference) around the unit?
What is a good approximation for the heat transfer coefficient of hydrocarbons inside 3/4" tubes?
What are the different types of equipments for the conveyance of solids?
Can you pls tell me how to calculate the amphere rating of cable in case of three phase supply but all load is single phase
Plz if anybody has placement paper of HAL mail me i m Chemical engg my id er.kotnala@gmail.com
What is difference between overall heat transfer coefficient & individual heat transfer coefficient?
MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)
Explain what are the affinity laws associated with dynamics pumps?
Why is post-weld heat treatment sometimes necessary for welded vessels?