Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why Drives are used to run AC motors?

Answer Posted / haneef khan gtr

Drives have to use for starting motor smoothly and control
the speed of its( as per requirement)except its it protect
the motor by any fault,with faults codes identification.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Logic using 1 kV or 1,1 kV grade in house wiring Low voltage cable. Explain/suggest? some use 1kV and some prefer 1.1kV grade insulation low voltage cable why??

1653


How to know any size of cable if there are not written on cable? Answer must be theurical not by experience.

2127


what is the significance of terminal voltage and phase sequence in the operation of paralleling of two generators?

2548


I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.

2115


we have consol make 3 phase servo stabilizer for cnc m/c. while installing the earth neutral voltage is 1.7 volts at stbilizer off condition and when stabilizer get on en voltage reaches 4.8 volts (new earthing is done and neutral is helthy condition all phase to neutral volts 440,442,441 v)why this happen.solution for cause.

7120


i want to run 11kv star connected motor in 6.6kv with delta connected throught inverter, is it possible?

2039


Both generator parallel condition shared load equally but one genrator taking ampere more than the other what are all the causes to make like this

1745


why effective resistance should be more than static resistance in transmission line?

2102


why the electrolyte level in lead acid battery is maintained 2.5 cms above electrodes?

1867


Is it possible to measure correct value of earth resistance & cable insulation ristance with out disconncting earth lead & both sides of cable ends? If not, any other method to measure ER & CIR with out disconneting from the system.

2104


why +24 v and -48 v give to BTS? If -48v protect from surge then why we not use -24 v?

1840


33kv substation lay out details & line to line & line to earth measurements

2623


What is the maximum and minimum rating of UPS?

1529


A ii kv 1200 A Breaker combination fixed in a cubicle. How many ampere Fuse is required? If fuse is not using, Why?

1989


how to find the capacitance value of the motor while running??

1934