Answer Posted / haneef khan gtr
Drives have to use for starting motor smoothly and control
the speed of its( as per requirement)except its it protect
the motor by any fault,with faults codes identification.
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
Why an ac solenoid valve attract the plunger even though we interchanges the terminal? Will the poles changes?
Name one of major transformer company in KSA ?
what is the reactance,capacitance & impedence electrical armoured & unarmored Cables.
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
how to calculate cooling requirement of datacentre from electrical load?
What are the ratings of VCB, MCB, MCCB, SF6, ACB, and OCB?
why and how current drawn by battery charger depends upon the altitude where it is located?
How do we calculate over and under frequency tolerance from generator data?
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?
which type of motor is used in automatic swing gate
Is there any reason that we get shock on touching phase wire because the earth is at neutral potential? Is there any reason that the earth is at neutral potential because the neutral is earthed in apower station
Is there any problem about which the drive (inverter) doesn't show/display the alarm and/or fault but instead of this , it doesn't work ? I want to know that could there be any kind of problem in the drive when the drive doesn't display the alarm and/or fault ?
what is mean by kneepoint voltage? when it will happen? ( my doubt is, if CT secondary is open means ct get saturation or blas? what are factors are required for calculations? plz give currect anws:
how to increase senstivity of ct
the winding of Generator and Motor is star or in delta ? and why