Thanks alot ripul. Then i have one more question how we are
designing multi-stage trims to avoid cavitation in control
valves. how we come to know cavitation occured.
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
what can of fault ofently come in vibration mesurement?
how to tune siemens sipart electro pneumatic positioner..plz tel me..
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
pls give me presant awerness quistion and answer in my emailid.
how does we calibrate a square root flow transmitter ,give an example and explain it step by step like range calculation , calibration hook up series connection , zero check , and how to apply pressure , and if not geting proportional output then what should we do ?
why we should maintain neutral earth voltage below 1V while calibration? why cant it be 1.2V or 2V
Why flow/pressure transmitter before control valve?
I want to know the questions asked in ONGC interview(after being selected in the written exam) for Instrumentation branch.Kindly help.
I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.
What is solenoid valve? Where it is used?
What is the use of GMV in turbine?
Name different parts of a pressure gauge. Explain the use of hair spring in the pressure gauge.
Explain the key components of control loop?
Instrumentation Safe Guarding test. How to determine the interval time of the test. eg:Halfyearly,Every year,Every three years etc.
what is the input of digital counter during the the calibration time?