what is earthed and inearthed cable or system?
Answer Posted / mzechlin
Here is your answer:
Consider a transformer wherein the secndary of the sinding
is connected to earth or ground such that it provides a
neutral path for current flow back to the transformer. The
connection to the "Earth" or ground is considered the
Earthed connection. It provides the user the ability to
split the voltage output with reference to the legs of the
transformer. Hope that helps
| Is This Answer Correct ? | 2 Yes | 4 No |
Post New Answer View All Answers
in cvt,there are two windings,1a,1n and 2a,2n.in my one project i use only one winding i.e.1a,1n. the other winding is not in use, so i connect it in open delta and want to close it by ibsertibg thermal resistor. the output of cvt is 132kv/115/sqrt3. plesae tell me exact value of resistor, so i may close it to avoid the resonance phenomenin. send me answer on this email adress please. aetcon-po@aetcon.com
I want to merge a cable..in between two metering Cubicals which contains CT's and PT's and Energy meter..before taking merger..what are the common things required?
why do we use spark detector inside the slip ring brush compartment 0ona slip ring induction motor?
why wire sizes are 3/29 or 7/29 and why not wire sizes are 2/29 or 6/29?
Please sent me some previous year question papers of BSNL-JTO telecom and RRB in ELectrical Engineering to varshashahi@yahoo.com
What do you mean by turns ratio of instrument transformer?
How to calculate or formula to calculate rhe power in 2 phase system ??
Why Transformer Neutral having one earth pit ( more earth electrode resistance) whereas body have many earth pit ( less earth electrode resistance)?
Define damping ratio.
IF DISTANCE IS 100METERS B/W AMP.METER AND CURRENT TRANSFORMER WHAT WILL BE AFFECT IN ACCURACY .METER CAN SHOWING ACCURATE CURRENT OR NOT IF NOT WHAT CAN I DO TO GET 100% ACCURACY.
How to synchoronize the generator (with gcb,GT) to grid????? ????? from Grid iam getting power (rated 400kv/20kv) through GT and its goes to UAT.,,ST.,, now my generator(rated 20kv ) ready.,, now iam closing my GCB.,, in GT iam suddenly giving 20kv on that Gt.,, what will happend
what is the difference between switchgear and circuit breakers and is there any difference between outdoor and indoor switchgear and circuit breakers , and how would you differentiate between switch yard and substation and grid station . thanks
upto how much low RPM we will run the commercial motor which is run through VFD without any problem occurs in motor.Motor rating Duty is S1 & RPM is 1400.
Whether IP65 enclosure box blocks ventilation if driver for LED have to enclosed inside IP65 box
Define non-touching loop.