Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the meaning of Dyn11 of Transformer.

Answer Posted / bhaskar halder

D means delta
Y means star
N means neutral
DYN 11 means phase difference between 30 degree HV & LV
side (& vice versa ).DYN 11 TRANSFORMER loss is very low
because phase difference is minimum but it is not use for
higher rating because phase angle is very minimum so HV &LV
side are shrot to each other.so very higher rating use DYN
5 & DYN 6

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

i have a 4 Mva transformer 34.5 kv / 480-277 v and i used 2 parallel 3200 amp bus duct for the secondary feeder using 3 ply of bus bar ( 3/8" x 5" ) as a common where the flexible link terminated and 6300 amps breaker for the main, the lower bus duct reaches 70 degrees and the upper bus duct reaches 55 degrees when i used thermal scanner. why the temperature is not balance when the load reaches 3600 amps.

1983


in cvt,there are two windings,1a,1n and 2a,2n.in my one project i use only one winding i.e.1a,1n. the other winding is not in use, so i connect it in open delta and want to close it by ibsertibg thermal resistor. the output of cvt is 132kv/115/sqrt3. plesae tell me exact value of resistor, so i may close it to avoid the resonance phenomenin. send me answer on this email adress please. aetcon-po@aetcon.com

2902


I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.

1909


What will be the effect of circulating current in HT xlpe cable when both the armour ends are grounded. Will the termination fils after some time in case of 33 kv supply.

2123


Can you explain about pole discrepancy scheme

2232


how to changeover ups in this power failur time?

2040


Sir pl provide 5 year sample paper for post junior engineer(electrical).I have currently applied for junior engineer (electrical) on RRB Ajmer

3689


send me all basic electrical question and answers

2967


Comparision of Air break circuit breaker, SF6 Circuit breaker and vacuum circuit breaker.

2421


WHY EARTHING NOT NEEDED IN BATTERY IN SUBSTATION

2019


armature is that part in which current is induced since in dc motor we supply current to the conductor so why we call it armature?

1962


On what principle electric motor works?

1246


Give details of your interested designation, the post you are interested to serve the company better and explain why you think you can serve the company better in such position if employed?

3387


what is the problem when i want to close a circuit breaker by local position it closes well.but when i close it in remote position it trips

1662


can mini-curcuit supply MIL-tested transformer !

2187