how can we derive power factor equation p=vi cos phi?
derivation?

Answer Posted / kiran antony

AC power flow has the three components: real power(Active power)(P), measured in watts (W); apparent power (S), measured in volt-amperes (VA); and reactive power (Q), measured in reactive volt-amperes (var)[3].
The power factor is defined as:
.
In the case of a perfectly sinusoidal waveform, P, Q and S can be expressed as vectors that form a vector triangle such that:

If is the phase angle between the current and voltage, then the power factor is equal to the cosine of the angle, , and:

Is This Answer Correct ?    8 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is a cstr and what are its basic assumptions?

684


What type of pump may be appropriate for a liquid near saturation, a low flow rate, and very limited npsha?

583


What are some factors to consider when trying choosing between a dry screw compressor and an oil-flooded screw compressor?

615


How can you quickly estimate the horsepower of a pump?

662


How do you design a vapor-liquid separator or a flash drum?

785






Dielectric materials in static fields

1774


How can hexavalent chromium be removed from aqueous waste streams?

625


Corenuts technology interview questions

766


Explain the different ways in which solids can be blended?

539


What is a good relation to use for calculating tube bundle diameter?

549


What is gibbs free energy?

609


Hi, I am in need of interview questions from Engineers india limited in chemical engineering.if any one has kindly post it to me soon.

5472


what is the difference between car seal close/open valves and lock close/open valves?

4968


Name some factors to consider when trying choosing between a dry screw compressor and an oil-flooded screw compressor?

555


MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)

1820