We are having proplem with the persperation smell in
ETT/ECHO room in our cardiac hospital.The 2 Ton of AC is
not conditioning the environment. We have to use exhaust
fan to through out of the room bad air. Could anyone
suggest how to coup with this effectively using chemical
engineering. Any permanent solution to neutralise the bad
smell.The Air freshners are not doing enough instead making
a bad odour.
Answer Posted / engineer muhammad amin baloch
1.First you must clean area with chlorinated water daily.
2.clean your conditioner filters weekly.
3.Today fragrance material is available in market put that
in your conditioner filters when it operates then it throw
air with fragrance.
4.Make sure ventilation system is proper if not then make it
possible to enter the fresh air.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What is the easiest way to extract hydrogen from water and the safest way to store it?
MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)
What is the most common cause of solid size segregation in bulk solid systems?
Explain what information is needed to specify a mixer?
We are having proplem with the persperation smell in ETT/ECHO room in our cardiac hospital.The 2 Ton of AC is not conditioning the environment. We have to use exhaust fan to through out of the room bad air. Could anyone suggest how to coup with this effectively using chemical engineering. Any permanent solution to neutralise the bad smell.The Air freshners are not doing enough instead making a bad odour.
Explain why is post-weld heat treatment (stress relieving) sometimes necessary for welded vessels?
What is the method adopted to minimize shell side pressure drop in a shell?
What is a good method of minimizing shell side pressure drop in a shell and tube exchanger?
Hi, I am Gurunathan. I am in need of ONGC, IOCL, DRDO technical test ( chemical engineering)and general aptitude questions. If anyone has kindly post it to me soon.
Oil and fat containing food items are flushed with nitrogen. Why?
What are the advantages of using gear pumps?
Explain what are the disadvantages of using gear pumps?
Explain can large temperature differences in vaporizers cause operational problems?
Explain the some guidelines for sizing a psv for a fire scenario on a vessel in a refinery service?