Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is Residual Voltage & Residual Current?

Answer Posted / vijay

Meaning of Residue:

A small amount of something that remains after the main
part has gone or been taken or used.

Now coming to technical understanding:

Residual voltage is the voltage that is remaining in form
of induced emf i.e., magnetic field in the windings of
generator or motor which will help in producing voltage in
generators and back emf in motors.

Residual current is the current which the sum of currents
in all the phases flowing towards and away from the node
must be zero, if it is not so the value which remains is
called residue so residual current.
I1+I2+I3+IN=0

To detect the residual current in power system RCCB & ELCB
are used.

RCCB= RESIDUAL CURRENT CIRCUIT BREAKER
ELCB= EARTH LEAKAGE CIRCUIT BREAKER.

My friend I think this information may help you.
If any correction is to be made please send the corrections
to my mail id: knownfellow7@yahoo.co.in

Is This Answer Correct ?    101 Yes 9 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what are the stresses in circuit breakers ?

2068


How may I enrol or get admission to your program?

1957


what is ATS & RING MAIN UNIT in Distribution System?And its Function.

2058


what is mean by drives?

2054


What is the formula of frequency ?

1515


what is advertised hop count

1824


Why neutral cable carry current.

2024


why single phase to grd test in HV cable?why not 2 phase at a time?

2325


how to check ac servo motor

2331


What is the formula to calculate the rating of power cable for three phase current.

2176


How do you calculate the actual power consumption of an inductive load appliance. Say, a deep freezer of 200watts

2195


WE ARE PLACE A NEW 75 KW MOTOR FOR JPF.IT IS CONNECTED IN M.C.C. WHEN WE ARE STARTING M.C.C.INCOMER IS TRIPPED.THEN WE ARE CONNECTED IN P.C.C WITH A MM30 RELAY PROTECTION THEN WE ARE STARTED MOTOR WILL RUN SMOOTHLY.

2117


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2197


can we use ZNyn11 transformer instead of Dyn11 transformer in distribution for effectively eliminating harmonics from the industrial loads.

5077


what is mean by D.O. in distribution line poles?

1741