Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the function of the serge absorber?

Answer Posted / raul

Surge absorbers are protective devices used to absorb the
complete surge i,e. due to lightening surge or any
transient surge in the system..........unlike the
lightening arrestor in which a non-linear resistor is
provided which provides a low resistance path to the
dangerously high voltages on the system to the earth......

Is This Answer Correct ?    21 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Can you used moeller lzm1 mccb in a dc system with 125vdc and 20ka short circuit current , beside is it have 24 or 48 volt shunt ? Beside how long current can through from An MCB shunt contacts? (like Z7-AS 24 V)?

2136


what is spadar bar .why I use in DC generator.

1974


what are the available sizes of pin type terminal lugs in the market today?

1891


what is load vs Torque curve & why it is used?

2123


What are the commonly used schemes for the bus zone protection?

1113


how to wiring it with contactor and timer together

1913


placing earthing pit in pathway is correct or wrong??. placing earthing wireGI1/18 inside walls is correct or wrong?. explain!!!

2214


explain all the classes with example

2015


difference between ac series and parallel circuit

2094


Power Factor Correction Panel (Manual & Automatic)

2286


What are the Formula of computing Back up Time of 500kVA UPS with 4 Battery Banks, each bank composed of 43 pcs of Batteries 12V150Ah. How to compute the Back up Time of UPS? We have also 3X500kVA UPS running in Parallel same composition as I write above.

1394


Why we use mho Relay in long transmission line?

1497


Thermal withstand capability under full short circuit conditions, in terms of number of times of occurrence of short circuit and corresponding anticipated percentage reduction in transformer life.

2493


HOW TO CALCULATE CAPACITOR BANK OR HARMONIC FILTER CALCULATION

2386


what is settable hystersis protection? If any body knows plz kindly post the answer..

2105