Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the working of AVR in AC generators?

Answer Posted / raul

AVR- AUTOMATIC VOLTAGE REGULATOR
AVR is a device used to measure any difference in the
generator terminal voltage and highly stabilized reference
value, and if it detects any difference, it controls the
firing pulses of the thyristors connected in the
system.....to change the output voltage of the pilot
exciter which in turn changes the output of the main
exciter n ultimately the generator voltage........
IN SHORT, IT IS USED TO MAINTAIN THE GNEREATOR TERMINAL
VOLTAGE B/W THE TRANSIENT STABILITY LIMITS so that d
generator remains in synchronism

Is This Answer Correct ?    17 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What does the letter CTNM in negative phase sequence relay means?

1739


In a tap changing transformer where is the tap connected, is it connected in the primary side or secondary side?

1078


transformer phasor diagram under load explain it?

2119


what are the breakdown voltage rating of mini- curcuit'transfarmer!

2117


although ckt breakers have taken the place of old fuse. But instead of it , these older ones are still used in the industries and homes ? why .... what are their advantages and disadvantages ? which one is leading and winning the race and competition ?

1937


use of choke in APFC panels

5693


Initially, when the input is not equal to the output — what type of response is this?

1024


Is a direct shorth ciruit on a branch MCCB in a Low Voltage Switchboard a correct means of tesing the performance for discrimination?

2289


how to find the Motor,s insulation Power?

1678


Why are cables rated for 40 KA for 0.25 Sec fault current rating?

1883


WHAT SHOULD BE THE BEST CURRENT RATINGS (PRIMARY / SECONDARY)FOR A CT INSTALLED AT THE INCOMING 11KV PANE? WILL IT BE CALCULATED ON THE BASES OF MAXIMUM DEMANT VALUE OR ON SUM OF ALL TRANSFORMER'S KVA? NOMALLY MAX DEMAND REPRESENT THE MAXIMUM OPERATING LOAD OF THE PLANT AND TOTAL KVA OF (SAY 5 NUMBERS TRANSFORMERS) REPRESENT THE CONNECTED LOAD. WHICH i.e. MAX DEMAND KVA OR CONNECTED KVA ARE BETTER TO USE FOR CT CURRENT CALCULATION? PLEASE ANSWER.

1850


Write masons gain formula.

1146


i want to know about torque of slip ring induction motor

2083


Is it possible to protect 3phase overload and earth fault of the 3phase system using two CT's.

2060


What is meant by Load Encroachment in OHL Feeder Protection?

3558