Answer Posted / meenakshi
simply speakin its because of the magnetostriction effect.
hey guys, i found the following link to be more informative
n understandable. to ave more knowledge on tis topic,plz
check it out without fail...
http://www.federalpacific.com/literature/drytrans/10transfor
mernoise.pdf
| Is This Answer Correct ? | 6 Yes | 1 No |
Post New Answer View All Answers
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?
why the India electrical supply transmission loss is high when compare to us
If we have to feed a housing complex having load 8MVA, than what would be the better option, either we first step down 33kv supply into 11kv & than 430v or we proposed no of 33/.44 kv transformer, also which option is economical?
Metal covered multiconductor cables shall employ a marker tape located within the cable running for its complete length in lieu of cable surface marking. Is it true or false?
What are the protection required for Transformer, motor, Line, Generator, capacitor, that all i have to refer which standard?(Like Transformer detail IS 2026)
how to calculate the step resistance for slipring induction motor,how you deside the no of step for that?
why we cannot protect 100% winding of an alternator by using differential protection?
calculate external resistance values to add to the rotor of a slip ring induction motor. STATOR- 415 V, 3 phase delta, 1100 A, 50 Hz, 1490 rpm, pf 0,86 ROTOR - 660 V, 590 A, 50 Hz. STATOR current at each steps STEP1-600A,STEP2- 800A,STEP3-1000A,STEP4-1100A.
We have 5 Distribution sections with variable loads&We have 3 Gensets(500kva,380kva&250kva) our total load is between 400kva to 600kva. so how could we connect 3gensets.
I WANT TO know WHICH WAY IS BETTER FOR CONNECTION BETWEEN POWER TRANSFORMER AND MAIN DISTRIBUTION PANEL. 1-IS BETTER WE USE CABLE? 2-IS BETTER WE USE BUS DUCT? my transformer rate power is 2500KVA
IF 8255 CONTROL WORD IS 94H,Tell the chip port work mode ?
What are the various types of BUSBAR Schemes? explain each
what is meant by 3rd hormonics ?
Draw a SLD of HT distribution EB grid up to users Transformer?
how to calculate current and voltage in a same circuit?