what is the meaning and difference between ELECTRICAL
DRAWOUT and MANUAL DRAWOUT?
Answer Posted / ranjana
manual draw out is the De-assembled procedure of
trolleys(VCBs) FROM PANEL.
A circuit breaker racking mechanism has a toroidal spring
connected between an inner and outer racking shaft. The
inner shaft is connected to the cubicle within which the
circuit breaker truck is moved while the outer shaft is
connected to the manual racking mechanism. The spring serves
as a direct mechanical force transmitting connection between
the inner and outer racking shafts when the breaker which
enters the cubicle is moved to the test position. After the
breaker reaches the test position, the inner racking shaft
is latched so that continued racking toward the connected
position charges the spring connection between the two
racking shaft members. The latch may be remotely defeated to
release the spring, thereby to complete the racking of the
breaker to its connected position under the influence of the
charged spring with operating personnel in a remote position.
| Is This Answer Correct ? | 2 Yes | 4 No |
Post New Answer View All Answers
Write down the design procedure of commutaj.
What is the effect on 3phase induction motor if current setting knob of DOL kept at minimum current?
What is excitation in case of dc motor?
Why we are using only Dyn11 tranformer in distribution system but not using a Dyn1 in distributing system?why not and advantage and disadvantage in both
WHAT IS THE SIGNIFICANCE OF VECTOR GROUPS IN TRANSFORMER? WHAT WILL BE EFFECT WHEN PHASE DISPLACEMENT CHANGES IN TRANSFORMER?WHAT IS THE NEED TO BE PHASE SHIFT CHANGE BETWEEN THE PRIMARY AND SECONDARY WINDING
how can see the ac indoor or out door ac which Tr
Is any generator is developed which is operated with out diesal or other expensive source?
What is effect of over voltage and under voltage on ACB
What is Surge Capacitor? Why it is use in Generator Circuit Breaker?
which network topology offers the greatest level of tolerance?
how the CT and PT is connected in the circuit during testing of transformer explain with diagram
why does make gain margin and phase margin on same plot.?
What will be the size of copper cable (each for 3 phase and 1 neutral) from Service connection Kit-Kat to Panel Board (i.e. to main switch) for a 6 pole 3-phase AC induction motor of 200 H.P. capacity? Amp-255 A, Frequency:- 1450 rpm.
why tertiary winding is used in transformer with diagram?
what is the working principle of a DG Set, Alternator, & exiter