How does one convert an AC motor into a generator?
Answer Posted / sidda raghavendra
* For an induction machine:
at the time of starting if we can set the speed of the
machine is just less than its synchronous speed it works as
induction motor as we must give electrical power as input
at the time of starting if we can set the speed of the
machine is just higher than its synchronous speed it works
as induction Genearator as we must give Mechanical
(steam,hydral or diesel and so on) power as input
*For synchonous machine:
Its all depend on only the input of the machine
| Is This Answer Correct ? | 7 Yes | 0 No |
Post New Answer View All Answers
List out the the types of Mounting Light fixture?
we have amp, voltage, kw, length detail then how to calculte copper & alluminium size of conductor of 3-phase induction motor
what is the operating time for LBB and how does the LBB relay realise whether cb is opened or not?
any one can explain the stages of a knee point which is taken during ct magnetising curve.
what is control supply rating of a machine
During FEED, you will have all the information with regards to cable. How will you calculate the MTO for MV and LV Cables? what are your considerations?
how to avoid electrical shock how capacitor store charges wat are the speed control of induction motors state faradays law flemings left hand rule what is rotary converter wat is transmission and distribution what are the sources of energy abrevation of acb,vcb,sf6,igbt what is output equation of transformer which test copper iron and iron loss are calculated what is eddy current draw a single line diagram (10 marks) draw direct online starter(10 marks)
please suggest some good universities with low cost iam in totally full confusion so please help me my profile gre 283 and ielts 5.5
What will be the voltage impact on secondary side of two transformers with different vector groups when both voltages are compared.
Stator of 3-phase IM has 3 slots per pole per phase. If supply frequency is 50 Hz, calculate the speed of rotating stator flux A 1000 rpm B 500 rpm C 1500 rpm D 1440 rpm
in power generator normaly voltagr betwween esth to neutral is 0 but my work place generator show the volatge is 60v any body know why? thanks
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
How to configure the drives in PLC, through Profibus commnication. And to how to address it?
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
Which test will be more severe for VCB?