what happens when we give ac supply to the dc motor?and why?
Answer Posted / rakesh kumar
It all depends upon whether the motor is a series motor or
shunt , if the motor is series then it would be running but
quite unsatisfactorily with increased sparking during
commutation and heating. however a shunt motor wont run
because of the high inductance of its field windings ( due
to greater no. of turns ) it will oppose the change in the
magnitude and direction of current which is th case with
ac .
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
State kirchoff current law?
How Load Factor, Demand Factor, Diversity Factor etc best applied in designing an electrical circuit? Is it allowed to consider these factors in each and every panel in an electrical distribution system? Can any body suggest a good book for reference?
What is the working principle of CFL & T5 tube light & 40W tube light with electronic ballast?
what are the different kind of cables used for transmissions?
george phenomenon of synchronous machine
What is difference between YNyn0 and YNyn ??
is it possible to start a motor in felid connected to a remote mcc
What is difference between Over Current & Earth Fault protection?
why effective resistance should be more than static resistance in transmission line?
what will happen if i connect 12 volt battery with 24 volt battery charger.
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
Why are cables rated for 40 KA for 0.25 Sec fault current rating?
State ohm’s law?
Why star delta starter is preferred with induction motor?
What is inverse definite minimum time lag relay? Where is it use?