AC voltage only create magnetic flux in coils, but in Solenoid
coil how 24V DC volt create flux and pick the plunger
Answer Posted / k.prakashchandra
Ans 3 is correct.DC solenoids are given momentary
supply.Then magnetic flux jumps from north to south with
the plunger.Reverse the polarity to make the plunger move in
the opposite direction.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
How we calculate the Multiplying Factor of Kwh meter for 3 phase alternator.
which model T or pie model is prefarable in power syatem
how we select ac fuse rating of an power inverter???
why the name trunking bus PT
What is resonant frequency?
please give me all the Alarm .Trip ,Safety Relays & Conditions of Diesel-generators mail me on ashokbabunhce@gmail.com
how to measure earth resistance of a substation
if flux and load static in dc motor and supply voltage increases 20% then what happened in speed
The efficiency of a 100kva transformer is 0.98 at full load as well as half load , for this transformer what is the Copper loss at full load ?
how the inner and outer body is separated in aircrafts?
Load transfer in 11kv double busbar switchgear - operation.
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
if any body have question paper of railway (section engineering),then plz send me .i will thank of him/her.
As we use capacitior bank in 3ph ckt for improvement of PF, why not we use capacitor in single phase domestric use, at our house their are many inductive equipments,like fan,mixer,tube choke,air conditioner they also draw PF... by using capacitor can they improve PF. if yes--what are advantage and how to connect a capactor in single ph,and which type of capacitor if no- what are disadvantages.
We have a couple of oil tanks at our plant. One of them does not have a lightning arrester installed. My question is it necessary to install an arrestor on every tank or will this particular one be covered by the arrestor installed on the ajdacent tank, Since all the tanks are close to each other. Basically, I want to know that if these arrestors or protection works in a parituclar area of effect or influence. Thanks