Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the make of breakers, transformers, generators?
What are their capacities and ratings?

Answer Posted / rajendran.m

BREAKERS. (M.V,H.T) RATINGS
Cromption Greavies. 125A.250A,400A,1000A,1250A
Siemens. 125A.250A,400A,1000A,1250A
L&T. 125A.250A,400A,1000A,1250A
ABB. 125A.250A,400A,1000A,1250A
TRANSFORMERS.
Kirlosker. 750 KVA,1250KVA,2.0 MVA
Indo tech. 750 KVA,1250KVA,2.0MVA
Cromption Greavies 750 KVA,1250KVA,2.0MVA

,

Is This Answer Correct ?    18 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Where can i get practical knowledge of solar system?

1455


armature winding of dc machine produce alternating emf then it convert in to dc by using commutator.But only we consider armature resistance why don't we consider inductive reactane effect?

2073


how to calculate the torque of a motor?

2139


Cb closed condition if there is a tcs fail whether cb will trip or not

1836


Why does the radius of armature is less than the radius of pole shoe?

2163


3 shows a 415 V, 3-phase generator supplying a 3-phase 415/110 V transformer. Draw the individual and combined impedance diagrams to a base of 10 kVA. Determine the system fault kVA and the fault currents at the 415 V and 110 V busbars for short circuit faults on the transformer input or output terminals. Work in p.u. values of impedances.

2659


What are dependent sources?

1184


Is there any reason that we get shock on touching phase wire because the earth is at neutral potential? Is there any reason that the earth is at neutral potential because the neutral is earthed in apower station

2017


slipring induction motor starting time Lrs operating why lrs starting time lrs outer body didn't get shock

1938


how does ELR works? explain

2695


is it true there's a big difference in using Cummins or Denyo...especially power output or leakage

1940


hi guys please tell me the procedure for mesuring the coil resistance of 3ph induction motor?

1899


HOW WE CAN REDUCE THE CIRCUIT COMPLEX OF STAR-DELTA STARTER .BECAUSE NOW WE USING ONE TIMER RELAY & THREE CONTACTOR FOR MAIN,STAR & DELTA ?IF ANY IDEAS PLZ POST.THANK U

2505


how to find number of run cable laying[LT side] for transformer & alternator secondary side? [above condition for getting output power transformer to main panel side] give the example.

2081


Explain the working principle of Synchronous Generator and Assynchronous generator?

2249