In a synchronous machine if the field axis is ahead of the
armature field axis then the machine is ?
Answer Posted / rakesh kumar
it will be a synchronous generator
Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
In aerodynamic turbines which element is NOT there a.stator b.compressor c. Fuel intake system d.fans
1.Can we use 6.6/11KV 300sq mm xlpe 3core cable for LT use (415 Volt). 2. If we use it for LT then what is the current rating
how single phase preventer works ?
what are the tests comes under the type test, what tests comes under routine tests.
what is the use of surge suppresser in 33 KV incoming panel. where it must be installed,inseries with incoming cable surge suppresser must be at incoming of the breaker are outgoing of the breaker
why do we have spikes enough to burn electronic boards, when generators are not grounded
(1)The demand for electricity , the amount of renewable generation available, the amount of fossil fuel generation available and the cost of the fossil fuel generation are shown in table below period(hrs) demand(MW) renewable (MW) fossil- fuel(MW) cost of fossil fuel(MW) 00.00 - 01.00 2000 1800 2000 30 01.00 - 02.00 2300 2500 2000 30 02.00 - 03.00 2500 2700 2100 45 03.00 - 04.00 2900 3100 2100 50 04.00 - 05.00 2700 2600 2500 45 05.00 - 06.00 2400 2000 2700 50 06.00 - 07.00 2200 1800 2000 36 07.00 - 08.00 2100 1600 2000 36 Assuming that the renewable generation incurs zero cost, determine an optimal generation schedule(specifying the amount of renewable generation and fossil fuel generation used in each period, the cost for each period and the overall cost for 8 hours.)
How to select cable the size, what is the parameters use and what is the formulas use for this cable size calculation?
what are the advantage and dis-advantage of 3 phase 4 wire energy meter?
i ha done my 10th with 71% ,ITI with 81% 11th with 75% 12th 43% apprentiship with 71% in SAT i secure 1390 ,TOEFL 27 i was refused four times and in all me interview visa officar told that i am not Qualify for study in USA but i completed my 12th yes i got low persentage in my 12th but i seen to much student they already got visa with them 3 or 4 backlocs so why they are refused me ?
how the aircraft outer body and inner body is separated ?
how we can decide that what value of ht line will come to any commercial building? (ans except According to the building load)
in 1-phase 230v,how in 3-phase 440v. in each phase in between 230v.
What is effect on in zone and out zone fault if CT chosen for phase side is Vk/2<5mA and Neutral side is Vk/2<15mA on REF protection of Transformer
What is star-delta transformer?