Why power factor should not be in leading (capacitive) mode
of any load.
Answer Posted / nithi
if power factor is leading ,this will leads the following.
system voltage increases-more pressure on
insulation-equipment life reduces-insulation break down-
over heating-over fluxing-core saturation-noise in core-
core over heating-may lead to ferroresonance(when resistive
loss is small)this will further complicate the situation-
harmonic production-increased THD-harmonic resonance-
penalty from EB-malfunction of control equipments & switch
gears-if overall system p.f. is leading,result in ferranti
effect-loss of power system costly apparatus-increased
losses-reduction in overall efficiency.
but actually,this will not happen in the power
system due to the presence of varios controls like
FACTS,shunt reactor,series reactor,synchronous condenser..
| Is This Answer Correct ? | 9 Yes | 1 No |
Post New Answer View All Answers
LT cable fault chaecking equipment and to find out the distance at what distence it failure . Name and where it is available?
What is difference between start imitation and start interlock for 3 phase motor protection ?
Haw to check conductivity of budbar
i had aplied Hindustan Petroleum corporation limited for the post of maintenance technician -Electrical,i want model questions,if anybody have please send it or please advice?
What is different type of Electrical curve and how it protects the equipment's while up-normal situation?
What are electric motors?
what is the size of ht cable of 33kv ht line and transformers ratings are 1 Mva and 5mva.please send formula also.
What is q factor?
Given a collection of points P in the plane, a 1-set is a point in P that can be separated from the rest by a line; i.e. the point lies on one side of the line while the others lie on the other side. The number of 1-sets of P is denoted by n1(P). The maximum value of n1(P) over all configurations P of 19 points in the plane is 18
3 phase Motor will be given 2 phase after 2 to 5 second we given 3rd phase so Motor Run sum-time in forward or sum time run reverse direction. All time phase sequence is not change. Why motor run in reverse direction? Please Explain........
What are the two segments of nyquist contour.
What is the meaning of HT Trivector Meter ?
How to calculate cable size in HT AND LT
A power transformer 4MVA/11KV/0.415Kv has been out of use in 12years. what maintenance actions/test need to be carried out before energizing.
What is rotating magnetic field?Discuss elaborately.