when voltage increases current decreases & vice versa why it
is so?
Answer Posted / kapil
for the same power.p=v*i.this is why as voltage increases current decreases
| Is This Answer Correct ? | 8 Yes | 1 No |
Post New Answer View All Answers
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
Explain Active power,reactive power,how its related to each other , & inductive ,capacitive.
How does a tertiary winding filter harmonic(espcially 3rd one) from entering into load system?
Define non-touching loop.
what is The difference between national electrical code and I.S.Code (electrical) and what is the value of NEC in electrical engineering field
what questions will be asked for 11/33KV licence interview APSEB hyderabad. Can any one share question and answers.
How to calculate Temp from Resister from PT100 equation,
What are marginally stable systems?
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
Why dry type cast resin transformers tap link blast in HV side while power shut down times on load?
How to calculate Voltage regulation of 22 KV Over head Line.
we have earthmat at 110KV substation.we would like to take earth resistance.b some says that by connecting earth megger terminals (C1,P1) at middile point of earthmat (at riser) will cause voltage gradient at other earthmat nods and dont get exat earth resistance.when connecting at end nods will get exat value . is it correct .please explain
What is the function of RCBO? What are the different sensitivity ratings & each application?
how we can find of current direction(supply comming/out going direction) when a transmission line passing through sides.
How can two 3 phase transformers of same KVA and Voltage be connected in parallel?