Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the per unit cost of generation of electricity at thermal,hydro,desael,solar,gas power plant

Answer Posted / k.prakashchandra

Several factors decide the cost.e.g. SGS in Karnataka is
supplying at 13p per unit whereas mini hydels charge about
Rs 3 per unit.However the cost in Rs may roughly taken as 1,
hydel -2,2. Thermal-3,3. diesel-8,4.Solar-4 5. gas -3, 5.
wind-3.5

Is This Answer Correct ?    1 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the minimum clearance between a 11KV 150KVAR capacitor cell and series reactor.can a series reactor can be mounted in the same structure of the capacitor cells structure

2202


How to calculate wire length,size & current? ( related to control panel)

2168


What is the percentage loss for aluminium wire for HT line more than 11KVa

2111


i installed 100kva ups. what KVA genset they should provid in input side? plz any update formula or ans with reason.

2328


what is the formula for calculating the phase clerance between two phases and phase to earth how to calculate the cable for a motor

2015


Difference between rating factor of cable and derating factor of cable?

1632


Single line digram for 11 kV to distribution use go,la and do

1807


1.ZEBRA conductor(large size) 2.KUNDHA conductor( small size ) 3.panther conductor(very small ) 4.lepard conductor (very very small)

2906


Why colled 440V to 3-phase supply.

2142


Logic using 1 kV or 1,1 kV grade in house wiring Low voltage cable. Explain/suggest? some use 1kV and some prefer 1.1kV grade insulation low voltage cable why??

1642


if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit

1866


What is the formula to calculate the size of Aluminium and copper cable?

1950


I WANT BHEL PREVIOUS QUESTION

2348


Whats the difference btwn a latch, port,data bus buffer? Do they all not hold data in d flip flops??

2385


give me applications of sequence bridges . (used in 3 phase un balanced systems)

1964