WHAT WILL HAPPEN IF WE START A MOTOR WITH STAR & IT IS
RUNNING WITH STAR CONNECTION INSTEAD OF DELTA
Answer Posted / rajib
As the applied voltage is 1/1.732 times, so the torque
produced is less, so less output is there.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What is meant by load angle of an alternator? Upon what factors does the load angle depend?
High voltage test procedure of in swgr board. why should measure millivolt drop on testing time?
What is synchro?
Whether should be the oil level in OCTC transfomer? It should be upto winding immersed completely or should be upto tap changer s/w? How it will affect the performance of the transformer. Rating may be 33KVA
What test must you do before powering up a circuit that you have been working on?
current transformer balance the power level on both sides. e.g in case of step up, at secondary side voltage rise but current decrease and vice versa in case of step down transformer. but how this power level remains same in case of current transformer and voltage transformer
What is maximum power transfer theorem?
What is meant by coupling capacitor?
A 500 V shunt motor runs at its normal speed of 250rpm when the armature current is 200A. The resistance of the armature is 0.12 Ω. Calculate the speed when a resistance is inserted in the field reducing the shunt field to 80% of normal value and the armature current is 100A.
What is meant by bus bar protection?
3 phase Motor will be given 2 phase after 2 to 5 second we given 3rd phase so Motor Run sum-time in forward or sum time run reverse direction. All time phase sequence is not change. Why motor run in reverse direction? Please Explain........
what is difference between window type and wound type transformers?where we will use window type and wound type transformers?
1- What is the Polarization Index number be good for 15KV 3c#500MCM electrical cable? 2- Can I use the IEEE Std 43-2000 to perfom the PI test? Thanks
How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.
what are the range of memory address in plc for L&T lx7 4A