Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why onlyseries motors are used as universal motors? why not
shunt?

Answer Posted / qureshi majid

Shunt motors are started directly through line,which may be
damaging to the armature and they need special starter
avoiding said damage,where as series motors have high
starting torque with load.without load, starting must be
avoided because empty running can get very high speed
exceeding limit may cause serious damage to the system .

Is This Answer Correct ?    6 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I don't understand why when we connect high voltage source in DC to electronic motor , we must add capacitor and resistor in parallel ? (I know that we use capacitor because we want to absorb the current that in the first second electronic motor in opposed with current course produce. ) what are the feature of Resistor and in such situation ?

1809


tell me some type of questions throught which i can prepare for exam and do my best

1944


What does the letter CTNM in negative phase sequence relay means?

1746


what is the main difference between power devices and signal devices

2140


An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The rotor reactance at stand still is A 2 ohm B 1.25 ohm C 3.15 ohm D 2.25 ohm

2214


EHV current carrying parts need to have smooth finish,then how can a 245kv GIS with emery finish can run so long?

1826


what is the power rating of CPU, CRT type moniter, LCD type moniter,scanner Approx.

2136


How would you calculate power loss in a resistor?

1021


Define the three phase formula fuse.

1817


What is BusBar integrity test and how it is conducted?

2160


How to calibrate or test an LT Air Circuit breaker 440 volts, 35 KA, 800 Amps ?

1873


What is the formula to calculate the rating of a three phase miniature circuit breaker

2083


What are steps to be taken while designing of DYN11 distribution transformer to achieve magnetising balance?

3486


can I improve the furnace power factor (10 mva transformer) by adding a capacitor bank before the transformer.Does system power factor vary a lot with the furnace PF?

2001


sir,in our plant we r using SATEC PM172E power reading meeters in HT panel side it is monitoring the MB data smart viewer(sever).but last one week we did not get readings inthe server only available in meeter.tell me how communicate meter and server. and also what steps we take for checking.

2185