Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the basic difference among IPS,UPS,EPS?

Answer Posted / qureshi majid

Ips-
Integrated power supply: used for integrated power consumption.
Ups-
Uninterruptible power supply:Battery used in the event of
power outage
Eps-
Electric power supply

Is This Answer Correct ?    26 Yes 18 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

We have studied about many techniques for finding the stability of system, ROOT LOCUS, ROUTH, BODE PLOT, POLER PLOT etc. In these which is used where. what are the difference among them... PLZ tell me.......

2098


how to calculate the fault in substation

2335


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2094


what is the effect of power factor of machines in starting current

1999


How select ELCB for 32amp. socket having quantity 12Nos. We have to do this wiring in PLANT. Please Also explain the incoming cable specification.

1821


which book to refer in electrical engineering for iocl exam & which book for general english.

2187


it is possible to rotate the DG engine dc starter with wrong polarity connections? why?

2198


WHAT DO YOU MEAN THE DIFFERENT TYPE OF CURVES OF RELAY LIKE STANDARD INVERSE, VARY INVERSE, NORMAL INVERSE, LONG INVERSE ETC....

1908


Where I can get the sample question for post of Junior engineer electrical-II For RRB Bhubaneswar.

2129


in 6.6 kv vaccum circuit breaker vaccum bottole vaccum capacity ????

1947


what is a speed of rotor when we give supply to stator of 50hz and as well as rotor of 60hz of an induction motor?????

1597


What is the minimum underground tank size capacity considered for firefighting purpose?

1902


What is the tests required for a 132 kV, 400 kV , 765 kV for a Circuit Breaker and Power Transformer before commissioning ?

1508


What type of DC motor would you see for a lift?

1049


Why we make earth connection with Transformer Body and What will be the minimum size of copper wire as per code with respect to KVA rating of Transformer?

1778