Answer Posted / amrit
He is talking about same KVA t/f.
we r not changing anything but the size... how?
keeping voltage per turn as same in both cases..
we decrease the flux in same proportion as the freq.
increased to keep freq.*flux = const.
now flux decreased reduce the area of the core to keep flux
density same.
Hence size of t/f will b small with high freq.
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
i have seen one 8.4 MW synchronous motor in a plant located in bellary it is fixed with brushless rotary rectifier ,anybody can explain its start up principle
internally connection of photvoltic module
what should be the no load current for 3 phase ac motors ranging from 5 kw to 1000kw?
The sodium vapor lamp is not glows when it is connected a distance of 5 meters above from gearbox, why ?
why 1.7Uo for HV cable Hi pot test?IE standard why?
testing of Vector Group – YNaoD II
How to calculate the Efficiency of Chiller
Why the cores of large transformers build up of circular cross section?
why transformer ratings in kva? & DG ratings in kva? & Motor ratings in kw/HP?
If symmetrical fault occurs at the terminal of a synchronous motor then how the motor will act...explain it..
what is the AC Plant and how can do the work with parts and picture tell us 150 Tr
The knee point of a current transformer is normally unique and known.So why in the nameplate of a CT they put the minimum value like this Vk> 400v.
what is the criteria for selection of conductor used for ehv ac electrical dischrge
I completed iti in2004 I was worked in A grade contractor can I get c licence
can someone explain that how the speed of the protection system affects the fault level calculation?