What is mean by PID controller? And what is its Long form?
Answer Posted / santanu sen
PID controller is also known as proportional integral derivative controller. The two main types of operation integral and derivative controller are used. The integral controller is used to minimize the steady state error of the response characteristics, it is the same as adding a pole to the transfer function of the control system. The purpose of the derivative controller is to fasten up the transient response, as the peak value is obtained earlier than the normal response, just as adding a zero to the transfer function of the control system. The proportional controller can be realized for two purposes:-
1. The derivative controller cannot be realized alone so therefore there must be a proportional controller for the same.
2. The proportional controller is also used to adjust the gain of the control system within the limits of the s- plane, otherwise may lead to instability.
| Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
Difference between On Line capacitor and Station Type capacitor.
what is the effect of power factor of machines in starting current
Why 3 phase induction motor getting supply in body if one of it's phase is cut
What is the height of DA, DAL, DB, DC & DDE tower?
how much leakage current is allowed in MC61A L&T make relay?
what is the affect of earth's magnetic field on the frequency used in aircraft???
battery capacity use of made?
what is th basic difference between a d latch time line and a d flip flop time line???
How much inductance or resistance require as a starter in series with induction motor of specific capacity(e.g. 5 hp) ? What is formula for it ?
how we can come to know that motor winding resistance which showing by DMM is right or wrong???is there any chart or something that we will compare & check???
How to calculate main incomer rating of APFC Panel ? Let's say i want to find main incomer for 11kV, 1000kVAR Panel.
HOW DOES THE ELECTRONIC ENERGY METER WORKS?
How to design inductive load for 3 phase 440v and maximum 5 amps for star or delta? Can we use a 15kW, 1450rpm motor for 15kW, 960rpm apllication?If yes.how......n.if thesame motor used what`s it`s sideeefect.
we are small scale industry in production of rice & rice bran. Pls let me know how to take contract demand for our industry.. (for information we have total 600.hp)
If the Brush of DC motor is shifted by 90 deg, then what happens to voltage and torque? Both voltage and torque are zero. how to justify the answer?