What does extreme points in VLE curve represents??
Answer Posted / mayur mittal
or boiling point pressures
| Is This Answer Correct ? | 5 Yes | 2 No |
Post New Answer View All Answers
How can metals be removed from aqueous waste streams?
Hi, I am in need of interview questions from Engineers india limited in chemical engineering.if any one has kindly post it to me soon.
What are some of the consequences of an undersized kettle type reboiler?
What is the easiest way to extract hydrogen from water and the safest way to store it?
In Galvonised iron and stainsteel pipes, in which pipe friction losses will more and why ?
MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)
How can you estimate the efficiency of a pump?
We are having proplem with the persperation smell in ETT/ECHO room in our cardiac hospital.The 2 Ton of AC is not conditioning the environment. We have to use exhaust fan to through out of the room bad air. Could anyone suggest how to coup with this effectively using chemical engineering. Any permanent solution to neutralise the bad smell.The Air freshners are not doing enough instead making a bad odour.
How to caliculate the boil up rate, dia and height in both packed and tray distillation columns and any referance books for the design.
Explain some of the consequences of an undersized kettle type reboiler?
Are you having any experience in antibody designing?
What is the method of determining maximum differential pressure during hydro testing of shell and tube heat exchangers?
Why do we apply on iron articles?
Are there any alternatives to scraping a shell and tube if a capacity increase will make the pressure drop across the exchanger too large?
What is an effective means of removing silicone from aluminum?