Troubleshoot to the device level basic process control
systems given the Process and Instrumentation Diagram?
Answer Posted / vishal patel
here i need process diagram or p&id
Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
Make a ladder diagram on LSL valve will close, on PSL valve will open and start the motor
We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.
what about your moleg in pogrees with company
typical loop drawing of a simple feedback control comprising of one transmitter and one control
Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72
basic connection and principle of axial shift sensor n differential sensors in tubine describes n draw......
Pl send the model question paper of mahagenco account officer post
how 3 out of 2 Logic/interlocks works? give brief explanation with help of diagram.
sir, give me placement papers and interview quistion of birla group company of copper.
What is feed factor and its Importance in cement industry? How we can solve feed factor?.
I need control valve ISA hand book. Is there any site to download that big book containing all the pages. Written by Paul Friedmann
what is droop in governer ,type of droop ,how it work
why direct mounted pressure transmitters is always installed with DBB ( double bleed block) valve in process line or top of the tanks ?
In VVVF DRIVES VOLTAGE IS ALSO VARY WITH THE FREQUENCY. HOW? WHAT IS THE DIRECT FORMULA RELATING THESE TWO.
send me model hpcl questions pleas..........my mail id mohideen.dharvesh@gmail.com