Answer Posted / www.islamqa.com
# PLC is first designed for 0n/off - discrete control, but
by time it had PID and analog algorithms.
# DCS from its start mainly designed for analog ad PID
control.
# now with great achievement in PLC h/w and networking
capabilities, with good engineering one can build his own
DCS from multiple PLCs - but it will not give the same DCS
features and functionality.
# DCS is pre-built system, ready and easy to use, has its
own compatible h/w and s/w integrated and tested.
It has features of:
- Instrument management.
- Alarm managment.
- Data collection and management.
- Smart, self diagnostic capabilities.
- Event and history recording.
- Advanced control strategies.
- Easy drag and drop features.
- Redundancy.
As mentioned, we can build DCS from multiple PLCs, but it
will not be the same as the prebuilt system.
Regards,
Ahmed Sabry
Control and Instrumentation Engineer
GPC - General Petroleum Company
ahmedsabry.online@gmail.com
CELL.: 00 2 0121367310
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
What is rang ability?
What is the diffrence between ff tx and non ff tx
Define cryogenic?
Can any one send me IOCL instrumentation question papers.. i dont know the pattern of the questions and what to prepare can any one help me on this .. my email id is anwarnishil@gmail.com
hii my name is sujith...i am preparing for HPVL GET 2010... so ,,,pls help me by send any previous questions or material to my site.....(Msujith_12@in.com) thank q
What is Alpha & Beta fctors related to Orifice Plate & its relation with flow?
any questions on motor and energy conversions machines?
How do you identify an orifice in the pipeline?
I need to know steps to Calibration Valve Guard......
HI friends.I am Surya a BTech in Electronics and Instrumentation Engineering.I am going to appear Relince Industries Ltd all India writen test very soon. so plz help me by sendind the probable questions about my subject.My mail ID is surya.barik@gmail.com.
Explain why plc require in analog input 4-20amp & 0-10 volt?
A flange is used for instrument connection for a system with a design temperature of 316C (600F) and a design pressure of 1000 kPa (145 psi). What is the class rating of the flange to be used for this application? Explain your answer
Why not come out analog output in ABB EL3020 when display show correct value
When doing a liquid seal on a differential flow transmitter , most of the time the sealing liquid will be heavier then the process fluid. For wich application will the sealing liquid be lighter than the process fluid if transmitter is mounted below the process line.
can anyone can let me know in Eurotron Micro cal 2+ calibrator in milli amps source mode we are not able to get 20 milli amps output it only produces 1.52 milli amps out, but display shows increase in milli amps , and err6 displays, let me know how to remove the err 6.