For a centrifugal pump if the pump is running and we close
the discharge valve what is the effect
Answer Posted / suzz0n
Discharge valve shutdown means , flow rate is zero and as from the pump characteristic curve we can see that for a zero flow rate there is still head developed in it, so pressure will be developed inside the pump without much affecting the centrifugal pump and cause damage in case of Reciprocating pump.
| Is This Answer Correct ? | 2 Yes | 7 No |
Post New Answer View All Answers
How to caliculate the boil up rate, dia and height in both packed and tray distillation columns and any referance books for the design.
What are the different ways in which solids can be blended?
What is happening when paint dries?
what is AZ431 & how to check it by using multimeter?
When specifying a cooling tower, should I look up historic wet bulb temperatures for my area or should I take measurements?
Explain the reasons of removal of particles from effluent gas?
How can you determine the largest impeller that a pump can handle?
What are the merits of using a falling film evaporator?
Explain what are the advantages of using gear pumps?
In a crusher where is the energy provided to it is used up for?
Are there any special considerations to be taken into account for combusting ammonia?
Explain the working of a spray condenser?
What are flameless oxidizers?
What are the problems that are associated with the expansion joints?