WHY WE CAN GENERATE POWER IN 3PHASE MODE ONLY NOT IN 4 OR
5PHASE
Answer Posted / sudhir
for 4 phase system ,phase difference b/w phase 0,90,180,270
deg.at every instant 0deg phase cancil by 180 deg phase,and
90deg phase cancil with 270 deg phase so resultant voltage
at everyinstant wiil 0.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
1 “earthing” for bonding of equipment and circuits to common plant earth electrode potential, 2 “protective earthing (PE)” when this bonding is required for personal safety provisions 3 “grounding” for interference suppressing bonding of screens, sys-tems with ground level 4. low-impedance earthing ? 5.primary earthing system and secondary earthing system what is that? 6.earthing electrode or mesh net earthing electrode ? very confusing , simple but very informative help required ? i will be very very thankful to you guys.
why need to be maintain power factor for industrial customer?
Determine a suitable number of slors and conductors per slot for the starter 1 winding of a 3 phase, 3300 V. SO Hz 300 rpm alternator. The diameter is 2.3 m
Why is a plain induction motor unsuitable for wide speed control?
PLEASE ANYBODY HAVE ELECTRICAL CIRCUIT DIAGRAM FOR CHMER PULSE CD 60M SPARKING MACHINE.PLEASE MAIL ME SUPRIYAAYYAPPAN@YAHOO.CO.IN.
what is is the potential diffrence between two phase ?
hello friends.. I have a doubt regarding the operation of dc machines.. I studied in a text book that a dc machine can be used as a generator and as a motor.. is this possible? If so,please send me the info about this topic.. you can also send your info to my mail.
What is the difference between isolators and electrical circuit breakers? What is bus-bar?
what is relay what is protection & contact multiplying relays where it is used function in brief
If 22 KV HT line, Current transformer is 25/5 then how to calculate multiplying factor.
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
why transformer tank is in rectangular shape what happen when it is in step shape
what does vector group Dyn11 tell us? also tell me how will u differentiate between phase lead and phase lag thru this vector group
How to detect voltage vector shifting in interconnection protection.
dg started in plc mode and load taken later one battery terminal connection will be disconnected by loose connection what will happen for dg and shall we connect battery terminals while dg in load time?