Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why KBr is used in FTIR SPECTROSCOPY and why is it necessary
to triturate KBr during FTIR analysis?

Answer Posted / sudhanshu raghuvanshi

KBr is an alkyl halide and any alkyl halide doe not show
any absorption spectrum in infrared region.......we can
also use kcl....for the ir of liquid we use nacl cells
because it is also an alkyl halide and does not show any
absorption spectrum in IR region.......

Is This Answer Correct ?    136 Yes 46 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the origin to prepare standard operating procedure

2405


which batch require to use for analytical method validation?

859


What is the Formula for coreletion coefficient in plhplc calibration

1883


for inorganic molecules require to do RS, Assay and disso?

777


what is procedure of actual procedure for registration of drug?

2056


USP methodology, EP methodology, IP methodology, among three if possible to use one methodology for qualify working standard to use USP, EP, IP ? Please explain...

2073


in OSD forms require to use gas chromatography?

874


how decide the clining method and cleaning method validation require for this perticular products?

822


We use hicrome 10 cxs column in hplc analysis....pls tell me.. what is the meaning of 10 cxs?

1784


How require to perform linearity as per ANVISA? What are the acceptance criteria?

1401


Why sometime potassium ortho phosphate mix with acetone use for sample preparation for hplc

1504


Hi sir if any product monograph not given known impurities (may be 5 impurities) specifications then how we require to proceed for inhouse formulation?

757


is it nessesary to do solution stability for 7 days?

821


we are performed SOR for a particular product the limit is -6 to -10.We face particular bathes it is not meeting the specification.we performed diffrent instrument diffrent analyst we are getting diffrent diffrent results.solvent is dimethyl sulfoxide what could be the reasion

1921


How can we confirm the HPLC column is end-capped or not? Is it possible to identify by physical appearance?

3264