Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how to write the program for single push button by using
ladder diagram

Answer Posted / praveen kumar m

PB k1
|---II--|--------------( )--|
| k1 | |
|---II--| |
| |
| PB k1 k2 |
|---II--|----II--------( )--|
| k2 | |
|---II--| |
| k1 k2 Y1 |
|---II-------I/I-------( )--|

PB= push button
K1 n K2= Contact switches n relay coils
Y1= motor(to switch on r off)

Is This Answer Correct ?    3 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Can any body help to get Rsemulator 5000 free from internet if possible then give me any link or any help .

2502


why direct mounted pressure transmitters is always installed with DBB ( double bleed block) valve in process line or top of the tanks ?

2061


What is profibus?

1132


How to calculate P,I&D value in PID controller ?

2151


what is a vortex flow meter,mass flow meter and electromagnetic flow meter.particular use of this.means in which condition particular meter is used.

2248


diff between neutral ,ground,phase , earthing and shielding?

2300


what is diffrance between FF & SMART, explain with difination

3225


A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.

2179


How to calibrate smoke Dectector

1639


Sir, I am working as a Instrument Engineer in Grasim Industries. Can any body provide question answer for interview purpose

2269


how can leve transmetter calibate in feild .and also put cv and flow plz .....

2248


sir, i preparing hpcl,ongc,barc,hal exams(instrumentation engg)pls send a placement papers

2334


I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.

1798


Why use ball valves on Gas pipelines instead of gate & or globe valves...means basic diffrence or use of these valves..how designers knows this type of valve with rating is required...

2355


How can you add value to this Industry if offered the job?

1604