Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the acessaries distribution transformer ?

Answer Posted / sudhakar(indotech transformers

radiator,shut off valve, butterfly valve, prv, pr device,
b/r, s/r, airplug, breather cup, porcelin bush, epoxy
metalpart, metal parts, breather, arcking horns, additional
neutral bushing, cable box, busduct, radiator, radiator
opening key, avr, rtcc pannel fl/fl valve, fl/fe valve def
valve, osr, oltc compartment, octc tap switch, tap switch
handel, mog, plain gauge, explosion vent, oltc handel,
diaphram, hardwares, drain valve, filter valve, sample
valve, aircell bag, conservator, conservator supporting
channel,thermometer pocket, lashing lugs, base channel,
rollers,inspection cover lv and hv side, top inspection
cover, tank cover, wti ct, neutral ct, marshling box dobule
window, single window, dia 100mm stem type model, oti with
stem type

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

power transmission pole used one support , that only for support or earthing

1969


Pl. brief about break-down maintenance of machine tool.

1815


describe the Operation of induction generators from bus bars

2329


Main advantage of auto transformer over two windings transformer is that A it needs no cooling B it uses only one winding C core losses are reduced D it has simple construction

2962


What will happened if the neutral of secondary of Xformer ( Star point) Note it's above KVA rated Xformer

1900


a battery is having capacity 100AH and 25% charging .if a load taking 10A & connected 6 hour .what is the final condition of the battery.

1630


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

2161


How to check the cable fault / hv test of transformer cable.

1895


Which motor is 3.3 or 11kV more reliable, in terms of efficeancy,maintenance, reliability.

2127


IF HT CAPACITOR IN ON POSITION IS THERE ANY LOSSES I.S I SQURE OCCURS IN THE SYSTEM

2177


why tertiary winding is used in transformer with diagram?

2260


how can i reduce sparking without stepdowning the voltage

2539


What kind of preventive maintenance are there for transformer?

2282


critically criticize the application of ring main unit in power system

1461


How to calculate the fuel consumption for 600kva DG genset which connecting with 25%load?

2135