IN DISSOLUTION TEST S1AND S2 AND S3 CONDITIONS ALL ARE
FAILED THEN WHAT IS THE DESSICION U CAN TAKE
Answer Posted / rc
Dear GUPTA, S2 AND S3 STAGE OF ANALYSIS WILL GENERALLY BE
DONE UPON THE FAILURE OF THE PRODUCT TO MEET S1 STAGE.HENCE
S2 OR S3 WILL GENERALLY BE PERFORMED THE NEXT DAY ,MAY BE
USING DIFFERENT LOT OF MEDIUM,APPARATUS ETC.HENCE THE REPEAT
ANALYSIS BY SECOND OFFICER DOES NOT ADD ANY VALUE .
| Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
WHY given much noise PDA dector then VWD Dector
Colorimtry
all types of questions asked at the cipla interview
Why Ethanol is Used for Standardization of GC Head space?
How can we calculate offset value pH measurment
in dissolution if one bowl got 70 percent 2nd bowl got 80 percent and 3rd bowl got 90 percent then how proceed?
How can we calculate "confidence interval" in analytical method validation? Pl. explain with example.
what type of question will ask in the interview of lab chemist.
how to set sample and standard concentration in RS method?
analytical method validation require to with respect to release specification or shelf life specification?
Related substance method equivalency on control sample or spiked sample?
I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?
which are the diffrent batches in the pharmaceuticals?
what is mean by dissolution biowaiver study?
What is gelatinization?