Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why indian power system having 11.22,33 KV ???

Answer Posted / arb555

The reason is some thing historical.

In olden days when the electricity becomes popular, the
people had a misconception that in the transmission line
there would be a voltage loss of around 10%. So in order to
get 100 at the load point they started sending 110 from
supply side. This is the reason. It has nothing to do with
form factor (1.11). Nowadays that thought has changed and we
are using 400 V instead of 440 V, or 230 V instead of 220 V.

IT HAS NOTHING TO DO WITH FORM FACTOR 1.11
OR
TRANSFORMER EQUATION 4.44*f*fi * smting

Is This Answer Correct ?    7 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the differance between HT motors And LT MOTORS.

2040


what is the electrical?

2169


why burdens of VTs is more than CTs?

1852


Please, if 1kw is equal to 1.25kva; how then do I know how many kva in 7.5kw?

1731


can indirect loading be called as phantom loading?

2253


what is the control circuit for operating the clean room air shower

2318


How can a equal potential zone be carried out in conductors?

1393


IF TVM OF TRANSFORMER SHOWS POWER FACTOR ON 33 KV SIDE AS 0.97 LAGGING AND ON 132 KV SIDE IS 0.75 LEADING.IS THIS CORRECT.WHERE IS PROBLEM.

2420


What are different types of control systems?

1302


I have made a 3 phase thyristor full bridge rectifier. But at the moment it is working only for the half bridge operation. Both the half bridges are on operation separately but when i put it into full bridge operation the oscilloscope output is zero. I rechecked that the pulses are correct for each thyristor. what could be the possible reason for this?

2031


How one can check the MAIN of a house wiring ?

2024


What are the commonly used schemes for the bus zone protection?

1115


Why do we mostly prefer to generate and distribute electricity in 3 phase and not in 4 phase or 5 phase?

1255


which type of effect of turbine and generator reverse power protection ?

4234


What is reactance, reluctance,capistance, pls give answeer in hinglish and be simply Jo asani we smajh m aa jaye

2213