Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

IN DISSOLUTION TEST S1AND S2 AND S3 CONDITIONS ALL ARE
FAILED THEN WHAT IS THE DESSICION U CAN TAKE

Answer Posted / k.g.gupta dr.reddy&

Phase I investigation should be done .
As a part of Investigation,Check the previous trend data and development of the product.Root cause is not identified then raise the OOS.
Second officer results also found OOS. We can conclude that the OOS results are due to the product behavior.

Is This Answer Correct ?    12 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In performance Check of GC Why Hexadecane Peak is Considered 

2987


what is the importance of peak purity in HPLC and how we can calculate through manul(not software)?

4420


about method developement in hplc

1665


From where require to take the RLD sample?

706


why sre you used Potassium hydrogen phthalate in standarisation of 1N NaOH and 0.1 N Perchloric Acid?

9693


If suppose 10 methods of dissolution given in pharmacopoeial for single content product then which method out of 10? or all 10 require to follow?

931


if your product is soluble in 0.1n hcl and water then which you choose as media from these 2 media?

630


how many types of balance calibration test?

2249


in which situation require to take incident in validation?

1651


what is the acceptance criteria for enteric coated tablets in 0.1n hcl validation in each parameter?

833


In the HPLC Calibration done wavelength accuracy done between 200nm-280nm .but not done remaining 300-400nm not done ?

858


which one is better separation in high pressure liquide chromatogram orlowpressure chromato gram in hplc

2117


For limit test of heavy metals in BP, Method C require that the substance is ignited at a temperature not exceeding 800 °C. Why confines such the temperature?

4003


why we use glass fiber filters use in some situation?

735


how you fix the limits of impurities?

786