Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why electric shock due to dc is dangerous than that of ac

Answer Posted / tahir saifi

BEST ANSWER ..both a.c and d.c are dangerous..but the chances of being safe is more in case of a.c..because a.c is flowing with pulsating means current flows in
positive cylce and negative cycle. when ever positive cycle
complete , alternating currrent come to zero value and if a person is strong enough to pull his hand then only he can be safe other wise he may die because of heart faliure.. but in case of d.c ..d.c attracts the person and repel after it absorb all the blood of his body..
...if we have low voltage a.c as well as d.c then a.c is more dangerous..because a.c frequency 50/sec and 3000/mint but heart beat is 72/mint so a.c can cause heart failure
.. but such a low level d.c is not strong enough to attract a person with vry high force, a person is strong enough to ovr come this force

Is This Answer Correct ?    3 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

2419


what is high - pot test. what's its use?????

2126


how to setting Load amps tripping time and extra settings for load Transformer protection relay with RMU panel using C&S model relay..?

1073


what is the efficiency of thyristor

1543


is it true there's a big difference in using Cummins or Denyo...especially power output or leakage

1887


Can we check ELCB constantly from R1 to R8 phase in 1 no DB?

1639


what is the grounding Calculation formula? spouse i want to provide grounding to 3phase 18kw motor or i want to provide ground to 3phase 10kva dry type transformere or you give me any exemple...... Thanks.

1829


How to calculate size of HT breaker with the help of Amp (current)? Please provide answers with examples.

2274


for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance

1893


What is a DC series motor?

1191


if 12v battery get discharged for 2 months after if we put charge it will charge again?how much time it will take to charge?

1875


how to select the no. of brushes in a lap winding?

2131


dg earth connect only in the amf panel or not why

2017


1.what is the difference between ct and cvt? 2.what is the difference between pt and cvt? 3.what is the difference between relays and circuit breakers?

2698


Installation resistance for whole installation of 16 kva & 25 KVA DTRA a) Between each conductor b) between conductor to earth c) installation resistance for each apparatus, each conductor to earth d) earth resistance for the system of earthing

1848