Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

IN DISSOLUTION TEST S1AND S2 AND S3 CONDITIONS ALL ARE
FAILED THEN WHAT IS THE DESSICION U CAN TAKE

Answer Posted / senthilkumar

Product further investigate and if need re sampling once
again will do it through oos and do re analysis

Is This Answer Correct ?    7 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why potassium dichromate is used in calibration of uv?

1990


Why irmoisture balance is used for corrugated box moisture testing

2404


why we use a particular hplc column for a particular compound give reasons?please

2753


on saturation solubility study data how we can find out the bcs class of drug?

904


if identification threshold crosses the limits then what next step?

870


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1601


Tell me about analytical method validation in QC

6183


If we do accuracy at same concentration at which linearity planned,what is the need to do linearity separately?

2310


what is mean by peak intigrity?

956


in which situation ion pair agent require to use?

743


How to choose the which salt is suitable for mobilephase

3256


How they found 1mL of K.F reagent is equivalent to 5mg of water and if we change the composition of K.F reagent, is it can neutralize more amount of water?

1780


in each media we require to use SLS? how to proceed?

792


if tech transfer fails whay require to do?

850


Why we used in n-butyl acetate water content terminology while in ethyl acetate we used moisture content terminology?

1865