Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How to test the thyresitor or SCR by multmeter?

Answer Posted / a.p

the thyristor will conduct in the forward direction and in
the reverse direction, it will show reverse recovery
voltage, thus a high resistance. Or we may put a diode in
parellel with the thyristor. The current gets diveded when
the thyristor is conducting. Else all the current flows
through the diode alone. In this way the thyristor could be
checkd.

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

ht side line to earth voltage

1524


Usually in the L & T make MCC feeders' power circuit,we have BMR after the MAIN CONTACTOR.,can we interchange their position, keeping the control logic same???

2054


In single phase ac ups supply when current is measured with tong tester neutral current is found more than phase current.What is the reason?

2072


why the making current is more than then the breaking current and if its true then its about a controling circuit or breaker power contact points

2016


How to discuss the phase shift of transformer considering open delta?

1407


What is cut-off rate?

1158


induction 3 phase motor terminal connection

2573


What information we need to prepare relay coordination chart

2265


what is the difference b/w ground & virtual ground?

2265


What is the meaning of HT Trivector Meter ?

2384


A 500 V shunt motor runs at its normal speed of 250rpm when the armature current is 200A. The resistance of the armature is 0.12 Ω. Calculate the speed when a resistance is inserted in the field reducing the shunt field to 80% of normal value and the armature current is 100A.

2450


A 100KVA SINGLE PHASE TRANSFORMER 10000/200V,50HZ REQUIRES 300V AT HV SIDE TO CIRCULATE FULL LOAD CURRENT WITH LV SHORT CIRCUITED.THE INTAKE IS 1000W.THE % OF REGULATION ON FULL LOAD AT 0.8 PF LAGGING WILL BE HOW MUCH AND THE SECONDARY TERMINAL VOLTAGE ON 0.8 PF LEADING WILL BE

2517


What is meant by Low Resistance Cable and High Resistance Cable.

1863


i want to know how to determine that a surge arrester work properly in 11kv system. and how to test a 12kv surge arrester

2121


If I have Energy Meter Ratio as 100:5 & Also I have CT Ratio as 50:5 then what will be my multiplying Factor(M.F.)

1929