What do you mean by zener breakdown and avalanche breakdown?
Answer Posted / saurabh goyal
ZENER BREAKDOWN
In heavily doped diode if we apply a reverse voltage
then it increase the electric field at the junction
and this high electric field leads to the breakdown of the
covalent bonds at the junction, this is called the zener
breakdown.
AVALANCHE BREAKDOWN
In a normally doped diode when a high reverse voltage is
appilied then the minority charge carrier get kinetic
energy and recive a high velocity. when electrons with high
kinetic energy colloides with covalent bond knock out the
electron from the bond.The newly generted ele. reapete the
same process.it leads to a chain reaction which makes the
diode highly conducting.
DIFFERENCE
in zener breakdown the breakdown of the covalent bond is
due to the high electric field but in the avalanche
breakdown the breakdown of the covalent bond is due the
colloision of the electron.
suggetions are wellcomed :sunnygoyal44@gmail.com
| Is This Answer Correct ? | 37 Yes | 3 No |
Post New Answer View All Answers
Instead of specifying SETUP and HOLD time, can we just specify a SETUP time for '1' and a SETUP time for '0'?
i am a student i need the technical questions ased in wipro
For explain what vertical and horizontal plates are provide in a cro?
What is input offset voltage?
Which gates are called as universal gate and what are its advantages?
Explain differences between microprocessor and micro controller?
Why is zener diode used as a voltage regulator?
What is the control range of firing angle in ac voltage controller with rl load?
is Motorola GSM Duplexer active or passive device?
write down a program to overwrite the contents of the flag register in 8085
What are the main purposes for which a common-collector amplifier may be used?
My lcd monitor not showing boot screen[dos]. Whenever I start the pc it shows blank screen till the windows xp starts. will you help me to solve this ?
Explain what is the meaning of tristate signal in electronics?
What are the different construction techniques in electronics?
Test on three subjects Physics, Chemistry & Biology are to be conducted simultaneously the number of candidates for the tests are 68, 36 and 72 respectively. Candidates are to be seated in different rooms such that each room will have candidates of the same subject and the load on each invigilator be the same i.e. the number of candidates in each room should be the same what is the minimum number of rooms you need for the purpose