what happen when ac motor is connected with dc current
Answer Posted / vikas tomar(from s.d.e.c. ghaz
The AC motor will not run when it is supplied by dc.
beacause as we know by the principle of electromagnetic induction that the emf will induse only when the flux changes w.r.t. time (i.e. when flux is alternating)e=d#/dt.Hence when dc is given,the flux produced would not be alternating,so no emf indused,no torque production,no motor revolution.
thanks.......................
with regards
VIKAS TOMAR.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
1. transformer design formula ? 2. how to calculate the primary turns and secondry turns ? 3. core types ? 4. how to find the primary current and secondry current ? 5. how to calculate the stacking factor ? 6. range of fulx density ?
What is slope...? Explain slope 1 and slope 2...?
What is meant by earthhing of a magnetic flow meter and when to use empty pipe detection?
why are installed water leakage detection system data centers & server rooms
Draw a circuit diagram in which if button is open we can use socket and bulb as a series test circit and if button is close than simple we can use socket as any load purpose.
Explain the term parallel path in dc machin ?
i will applied in 1U-1W on 440 volt primary delta side. what is the result of magtic balance test
What are the section criteria for cables. Now everywhere XLPE power cable is used or PVC is also used?.
What should be the magnetic balance test values for a 3 phase delta/star connected single primary dual secondary winding transformer (90 MVA / 2 X 45 MVA TRANSFORMER)
sir i am apearing for nic exam.i dont know exam pattern.can you please send me some model papers
Dry type transformers
what is servo motor and how it works?
The knee point of a current transformer is normally unique and known.So why in the nameplate of a CT they put the minimum value like this Vk> 400v.
1. How many types of mangers? 2.How many types of capacitors? 3.pls tell me normally types alternator problems?
Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.