Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

can we run a motor rated 50Hz,415vac,1440RPM At higher speed
then rated on name plate with the help of VFD /drive on long
term basis.wheater it will effect the motor life

Answer Posted / farooq malik

VFD varies the frequency of the motor from 0 to 100 persent
at the same time varies the power of the motor. Maximum
frequency it can go up to, is 100% which is 50 hz (Supply
frequeny). so the full speed is at 100 % freq, (that is at
50Hz)which as per name plate is 1440. hope this helps.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

HOW TO SET THE EARTH FAULT SETTINGS IN ACB????????????

2114


What is the basic principle of operation of alternators/dc generators?

1047


what the principle of sincroscope?how it works?when it needed?

2238


Transformer diagram mention each parts ?

1989


why would amp draw on neutral wire be as much as amp draw on the hot leg.

2043


How will change the frequency in distribution side?

1738


Why phase sequence must be same in any ht motor or generator circuit?if phase sequence doesn't same whatever will be affect on circuit?

2148


Dear sir, By which formula u can calculate for a particular kv line there is a range of mw.

2059


What is the different between digital phase converter and ordinary phase converter?

1096


What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer?

1948


Distribution transformer we provided 2 separate earthing pit for Body and 2 separate earthing pit for neutral,we can not connect separate body earthing pit to other earthing pit but we do metal glanding in secondary side cable termination in both side, transformer and PCC panel (LT Panel), is this safe for transformer and other equipment?

1677


What do you mean by screen of power cables?

1715


What is steady state response?

1248


What is the percentage loss for aluminium wire for HT line more than 11KVa

2050


how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

2152