Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why nearly all the voltage levels are in the multiples of 11
like 3.3 ,6.6 ,33 ,11 kv.....

Answer Posted / nisarg d. patel

In India we provide an offset of 10% overload on the rated voltage level to easily accomodate the varying overload.So in accordance with this, 10 KV becomes 11, 60 KV as 66 and so on and so forth.But this convention is not followed in EHV above 500 KV where we follow the international transmission voltage levels like 730 KV, 1200 KV and so on.And also because the form factor is 1.11 so it becomes symmetric to have the transmission level as 1.1, 3.3 etc.

Is This Answer Correct ?    6 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how we calculate electrical load on a building according to area?

2788


condition Autotrip facia come on control panel of electrical transmission line?

1568


how can you size an automatic voltage regulator?

2350


What is meant by Load Encroachment in OHL Feeder Protection?

3625


what will happen when the dc supply is given to the capacitor?

1521


Does the direction of rotation of d.c. Shunt motor would get reversed if the armature current and field current both are reversed?

1150


What is the method to solve circuit using source transformation?

1140


How to calculate pitch, gauge of winding wire, and No. of turns for 30HP, 3 phase, 4 poles 50Hz, 380V induction motors

1929


If one lamp connects between two phases it will glow or not?

1087


What is the settings of distance protection relay in 400 kv line

1684


what is the formula of starting current of 3phase and 1 phase motor???

2077


100 MVA 3-phase alternator with earthed neutral has a reactance of 5 ohms per phase. what will be the fault MVA of generator.

2365


What is the count of hvdc transmission lines in india?

1088


Explain Energy and Power signals?

1759


what are the specifications we must look at to select a relay for any capacity motor?

2033