i want prepare power grid exam what are book we want refer
for electrical ?
Answer Posted / chandra sekhar
Power Grid exam is perhaps the toughest exam in Electrical
engineering in India. It requires a good schedule and lot of
effort. Here are I provide a list of standard text books for
all competitive exams in electrical trade
SUBJECT AUTHOR
Network Analysis Van Valkenburg
Electromagnetic fields William H. Hayt
Electrical Machinery PS Bhimbra
Electrical Mach9ines Nagrath & Kothari
Power System Engg. Nagrath & Kothari
Electric Power Systems CL Wadhwa
Automatic Control System Benjamin C. Kuo
Control System Engg. Nagrath & Gopal
Electrical & Electronic
Measurement and Instrumentation AK Sawhney
Integrated Electronics Milman & Halkias
Millman & Grobel
Digital Logic & Computer Design Morris Mano
Power Electronics PS Bhimbra
| Is This Answer Correct ? | 8 Yes | 2 No |
Post New Answer View All Answers
if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit
What is the instrument to check the rotating diode fuse of alternator in running conditions?
What is the effect of positive feedback on the stability of the systems?
write down the formula of cable size in RM if current is 50Amp.
how to electronic energy metter failed in electomagnectic fild passing in the metter and which thing to defect more on metter.
Why do you have to use Protecion relay with the function MTB ( Mechanical Trip Button ) for electrical system.
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
how to meas-our losses for L.T & H.T
can any one tell me about the Extra low voltage systems?From where we give supply to these type of systems??
1)How much current can a 3-1/2 core 100 mm wire carry? 2)What are the special cables required for explosion proof wiring? 3)In case you do not have coal and salt for earthing, how can you achieve good temporary earthing? 4)One horse power single phase motor is more likely to get hot than a one horse power 3 phase motor. Is it true or false, if true why? 5)What are the different types of soft starters for large motors?please explain?
How to address the servo drive for motor
pls tell us AC plant are how do work and parts name with picture
i am going to give the JSEB,RANCHI exam for power plant,so i need some samples of papers related to that,so please send me these papers by my mail id.
How to size Air Circuit breaker (ACB)? What is the most important factors?
state the disadvantages of carbon filament???