Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why we oil in tranformer/

Answer Posted / sagar parmar (getco)

Oil is used for the 3 purpose,

1. it provide insulation

2. it provide cooling of the windings.

3. with using oil we can take DGA (Desolve Gas
Analysis)which help to find out internal fault of x'mer

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to calculate pitch, gauge of winding wire, and No. of turns for 30HP, 3 phase, 4 poles 50Hz, 380V induction motors

1928


If 100 KAV USP dedicated earth got disconnect / Cut. What will happen at load.

1959


ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?

2019


In constant power region of 3-phase IM torque-speed characteristics, if frequency increases flux A does not alter B decreases C increases D none of above

2233


1.Can we use 6.6/11KV 300sq mm xlpe 3core cable for LT use (415 Volt). 2. If we use it for LT then what is the current rating

1760


What is the real function of reverse power relay in generator panel while syncronising?

2180


Please tell me the earthing procedures adopted for the STAR-STAR 3 Phase transformer in india and give a better sugession for earthing

1951


how to find the Motor,s insulation Power?

1757


what is the size of cable for 15kw motor and 85 meter cable length using with vfd

2361


RATING OF LIGHTENING ARRESTER FOR 11 KV LINE IS 9 KV is ok ,but haw to calculate the KA rating?

2077


What is the criteria that generally follow by distribution licenses to fix contact demand of their industrial customers?

1520


What are IR values and what it should be for coil and for insulator

2985


what are the types of electromagnetic forces developed in practical transformer?

2620


I need bhel previous year quetion papers for electrical engineering department.I searched but i could not find out

2083


in Telecom DC system-why positive +ve is made earthed.and - ve is fed to load.

2689