Why generally the transformer primary is connected in star
& secondary in delta
Answer Posted / rekha goley
i think the reason behind this is that we know that vp=vl/1.732 and il=ip for star connection....similarly for delta connection vp=vl and ip=il/1.732....means we can say that line current is i.732 times the phase current in delta connection ......and we dont want more line current at the recieving side because this leads to more losses and due to heavy current our transformer cud be burn,it can be happen only in that case if we connect our secondary side in star although in some app.we need its reverse also........thats why we always connect primary side of transformer in star and secondary side in delta........thank you...
| Is This Answer Correct ? | 0 Yes | 2 No |
Post New Answer View All Answers
For an induction motor wat is the loading/unloading cycle duration or interms of L/UL ratio/ percentage?
is it possible to have dc motors on single chip
1.what is meaning of curve into a mcb. 2.what is basic reason changing of curve
what is the size of cable for 15kw motor and 85 meter cable length using with vfd
what is PID control in VFD drives?
what is the terminal voltage of dc series generator running at rated speed at no load?
we have a lot of model of rectifier but thyristor rectifier is the most rectifier that use in power system. Do you know why this rectifier is used?
11KV AND 22KV NETWORK KW CAPACITY IN RING AND RADIAL?
can I improve the furnace power factor (10 mva transformer) by adding a capacitor bank before the transformer.Does system power factor vary a lot with the furnace PF?
what is the use of power transformer in GSS.
Dear Sir/Madam, I have one questions we have three steam turbines and one Gas turbine and our industry linked with the public network, we have protection system one of the protection is reverse power we can export just four MW only i would like to ask about how to calculate the reverse power. Thank you in advance best regards
i am electrical and elctronics engg passed out in 2009 want to attend for reliance placements.plz send me apttitude ,technical and hr question answers to my mail plz. my mail id-kat.bindas@gmail.com
How PADO software increase the efficiency of power plant?
Why space heater is required for each verical bus bar chamber? if one space heater is adequate or not for anti condensation?
Draw the wave shape of armature current in a generator subjected to a sudden three phase short- circuit at its terminals. Define various reactance of generator from this wave shape.