What is mean by PID controller? And what is its Long form?
Answer Posted / thirunaavukkarasu
PID - Proportional plus Integral plus Derivative Controller.
This PID is used to reduce the steady state error obtained
in the output waveform. Steady state error does not allow
waveforms to settledown easier.
Proportional is used to process the present data of the
system and Integral is used to process the present plus
past data of the system where as derivative take the future
data also into account.
| Is This Answer Correct ? | 7 Yes | 0 No |
Post New Answer View All Answers
Is there a diode made that works with AC 120 volt 20 amp? If so can it completely stop all current flow in 1 direction at all times?
How you calculating the 30 Hp 3 phase AC motor of power what size of cable is used for this motor?
Difference between Earthing Truck & Earthing trolly for HT panel
What does the term supermesh means?
Mention the methods for starting an induction motor?
How to work E.L.C.B and how to connect in circuit.
What is the previous name of Cox's Bazar
During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP
Dear all i am kumaravel. now in chennai. my work is control and relay panel auto cad designing.up to 11kv to 400kv then question is i am improving my knowledge. i want some books name and auther are available for this C&R panel related. plese any one help me
Dear sir, How to calculate 3.5 core pvc aluminium armoured cable meter wise carrying amps rating.Please give the solution with a good example.
actually i can't understand what is 3dB ? and it's really not clear to me.please any one let it me be cleared.
If we are given a 10 amp cable type and asked to calculate the number of cores used and the thickness of the cable, how do we do it?? please help...urgent!! i hope the question is clear enough!!
Is neutral transformer can be called as control transformer?
During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.
How select ELCB for 32amp. socket having quantity 12Nos. We have to do this wiring in PLANT. Please Also explain the incoming cable specification.