Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

A dc motor running on dc drive whose input is 3ph AC what
will happen if we change the phase sequence of dc drive for
e.g (R Y B) is connect as R B Y, will the motor run as same
as previously running before changing phase without any effect

Answer Posted / anil bhatia

this answer is for Mr Arun Kokje . you can ask equation in proper place not in answer side .find the initial current and time to reach this motor to run in running in full speed current. the initial impedance of this motor is very low (300HP), it is just create like near to sort circuit current for 1250 KVA DG.
soft starter will solve your problem .

Anil Bhatia

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Is there any Electrical supervisor license which gives permit to work whole India rather than individual state??

1872


What is the Basic Difference bitween Long Shunt Connection and Short Shunt Connection in DC Generator?

2348


A double circuit with dog conductor 66KV Transmission line from wind farm evacuation to feeding substation having capacity of 25MW for transmission. Can same transmission network be considered for further expansion of Power & how much in MW. If we need to expand next 10-15 MW more will there any augmentation is required in transmission network? Kindly reply asap.

2198


WHAT IS IM (INDEX OF MOUNTING )IN MOTORS

2038


why we use copper earthing for neutral while for body GI.

6154


What are the types of control system?

1428


why we use the 100% and 95% stator earth fault protection for the synchronus generator ?

2309


State the factors, for the choice of electrical system for an aero turbine.

1167


I have a current transformer with 1 main reading meter with transformer outside the building and a control panel having 5 CT reading meters with black round coils inside the building. I want to know, A) when current pass through the Transformers, will the current be reduced or be the same and after that B) when current pass through the CT meters with black round coils, will the current be reduced or be the same. C) in the above process will the reading of the main meter be same or different, from the total reading of all the 5 CT meters.

1819


What is the selection process of breakers. Can any one please give a formulation on same?

2160


what is x'mer ,isolation x'mer & yltra-isolation x'mer?????

2482


How to select batteries required for ups and the inverter if we Known load? And how AH is selected of battery?

1454


1. What is the exact formula for one weber? for example,(one ampere = one coulomb electron of electrons crossing a point of conductor at one second. i.e, 1A=1Q/1sec)

1896


HOW TO DESIGN THE body EARTH cable(Copper Conductor) size for 60KVA UPS?

1999


I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?

1683